Liebert NX 20kVA UPS Module 38SA020C0CFJ 3-Phase 208V & External Maintenance Bypass Cabinet 38MB0200AC6ML
Items are Used with Normal Wear and Tear, Pulled from a Working Environment.
Liebert NX 38SA020C0CFJ (UPS Module)
Power & Ratings
Electrical Ratings
Items are Used with Normal Wear and Tear, Pulled from a Working Environment.
Liebert NX 38SA020C0CFJ (UPS Module)
Power & Ratings
- Power Capacity: 20 kVA / 16 kW (at a 0.8 lagging power factor).
- Topology: True On-line Double-Conversion Solid-State.
- Overload Capability: 125% for 10 minutes; 150% for 1 minute (with a true sinusoidal waveform).
- Nominal Voltage: 120/208 VAC, 3-phase, 4-wire plus ground.
- Voltage Window: +10% to -20% without discharging batteries.
- Frequency Range: 57–63 Hz (60 Hz nominal).
- Input Power Factor: 0.99 minimum at full load (achieved via an IGBT-based power-factor-corrected rectifier).
- Reflected Current Distortion (THDi): Max 4% total harmonic distortion at full load.
- Nominal Output Voltage: 120/208 VAC, 3-phase, 4-wire plus ground.
- Voltage Regulation & Distortion: ±1% for balanced loads (under 1% THD for linear loads).
- Dimensions & Weight: Measures approx. 23.6" W x 32.5" D x 63.0" H and weighs around 551.2 lbs.
- Operating Conditions: Operates from 32°F to 104°F with low acoustic noise (<54 dBA).
- System Features: Includes Softscale™ technology for scalability, an integrated static bypass, and Liebert Intelli Slot monitoring ports.
Electrical Ratings
- System Input Voltage: 208 VAC, 3-phase, 60 Hz nominal.
- System Output Voltage: 208/120 VAC, 3-phase, 4-wire plus ground.
- Maximum Current Rating: 200 Amps (indicated by the 0200 in the part number sequence).
- Maximum Continuous Load Current: Form-fit for maximum loads up to 69A input / 56A output on 20 kVA setups.
- Short Circuit Rating: Typically rated to withstand standard electrical faults matching the 35kA withstand criteria of the companion NX series.
- Bypass Interlock System: Equipped with internal mechanical interlocks or trapped-key (Castell) lock logic to prevent an accidental out-of-phase connection between the inverter and utility power.
- Switch Elements: Includes manual rotary or heavy-duty circuit breaker switches for:Normal Input / Rectifier DisconnectBypass IsolationMaintenance Bypass (Maint. Switch)
- Wiring Method: Features dedicated hardwire-ready terminal blocks accommodating top or bottom cable entry.
- Enclosure Material: Heavy-duty, durable powder-coated steel housing designed to sit flush or stand directly adjacent to the Liebert NX UPS tower.
- Service Access: Full front-door access with internal protective dead-front safety shields to prevent accidental contact with energized busbars during maintenance.
Specifications
| Condition Description | An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent working condition. This item may have cosmetic blemishes and may or may not be in original packaging. See the listing description for full details. |
|---|